A close up of the shadowside of solar cart.Notice declination
staff. Notice PV panel load disconnect switch. Notice hinges for panel. Notice
twisted 14 gauge wires coming out of panel instead of 12 guage wires. This is
cart #2. Notice second battery mounted in PARALLEL. This doubles your amps but
mantains 12 volts dc out put to inverter. It is amps which determine how long
the inverter runs although volts are proprtional to runtime also.As the battery
discharges voltage drops until cutout. Notice position of cart on level ground
facing sun. Notice the position of 2x4's used as spacers and mounting surfaces.
Always keep DC wires as short as possible to prevent transmission losses. Always
use the lowest number guage practical, i.e. the biggest diameter. Cables to
inverter recommended 2 guage. The parallel cables connecting batteries are 6
guage. The regulator came factory wired with16 guage I but used 12 guage or
doubled up 14 guage for in and out connections to it.